HGM Series   Natural Gas Heater Module

  1. Electronic ignition with pilot
  2. Incoming power 120 Volt or 240 Volt 1Ø
  3. 24 volt control system
  4. On/off burner switch
  5. 1/2" schedule 80 vertical coil assembly with 7 pancake removable coil heat exchangers
  6. Natural gas or LP-gas fired natural draft with aspirating-type burner, 10 inch stack
  7. Powder coated fram assembly
  8. Fork Truck accessible
  9. Inlet and outlet quick connects
  10. Pressure relief valve
  11. Adjustable thermostat
  12. Quality gas valve with regulator (maximum imput 1/2 PSI)

Gas Supply Line

ADDITIONAL FEATURES:

  • Draft diverter inlcuded
  • 3/8" x 12' jumper hose with quick connect included ( to hook up to existing pressure washer)

OPTIONS

  • LP Gas
  • 460 volt, three phase incoming power option

Natural Gas

Gas Supply 7-8" water column input

LP Gas

Gas Supply 12-14" water column input

Recommended Pipe Sizes for Gas Supply Line

Natural Gas

Distance from Unit          Pipe Size

To Regulator

-------------------------          -------------

0-50 feet                            1 1/2" 1PS

50-100 feet                        2" 1PS

100-200 feet                      2 1/2" 1PS

LP Gas

Distance from Unit               Pipe Size

To Regulator

-------------------------               -------------

0-50 feet                                 1"  1PS

50-100 feet                            1 1/2" 1PS

100-200 feet                          1 3/4" 1PS

In the Dallas / Fort Worth Metroplex?

Call today to receive a free demo of the HGM Series.

Contact Marty Davis at Metro (817) 695-1660 for pricing deals.